1, suggest customers buy a temperature and humidity instrument, placed in air conditioning room, monitoring the temperature and humidity of air conditioning room
2, customer control the environmental temperature and relative humidity content of the table to understand the requirement of environment and the low temperature water is set to 22 degrees, cutting machine temperature (
Air conditioning room temperature)
Below 26 degrees, the environment relative humidity (
Relative humidity of air conditioning room)
To ensure the below 75%, if the environmental relative humidity (
Relative humidity of air conditioning room)
More than 75%, 85%, for example, the ambient temperature (
Air conditioning room temperature)
To adjust to 24 degrees, or there is a risk of condensation inside.
The environment temperature (
Air conditioning room temperature)
Numerical and environment relative humidity (
Relative humidity of air conditioning room)
If intersections corresponding values less than 22, implement internal condensation, if higher than 22, device inside there is the risk of condensation, customers can reduce the environment temperature (
Air conditioning room temperature)
Numerical and environment relative humidity (
Relative humidity of air conditioning room)
To improve.
Or set of air conditioning cooling and dehumidification function, retainer environment temperature is not more than 26 degrees, at the same time keep the environment relative humidity is less than 60%.
Advising clients per shift attention to record the value of temperature and humidity table, in order to find problems in time, to prevent the risk.