In the eyes of many old users, may be cutting machine operation is very simple. Indeed, compared with the traditional sheet metal processing technology, the role of the cutting machine is to simplify the process, to do subtraction processing way. Simple operation, start-up and shutdown action more is a primary user feels very simple action, but the correct operating mode, good habits of operation can effectively reduce the equipment failure caused by the wrong operation, prolong the service life of equipment and stability at the same time.


so, cutting machine start-up, shutdown of the correct operating mode is how?

boot operation:

1. Check before starting the machine operates within the scope of any obstacles;

2. Open the total power switch and the branch control power switch;

3. A voltage stabilizer and check and running state;

4. Open switch, regulator air conditioning until the appropriate temperature;

5. Open device 20 minutes after the open air compressor and check the running status;

6. Open air pneumatic control valve and open person and check the running condition and air pressure;

7. According to the need to open the cutting auxiliary gas control valve, check cutting auxiliary gas pressure is normal;

8. Open the machine power switch, press power on button to start the machine tool control system, after waiting for control system to start the normal machine back to the origin;

9. Open the power switch operation more than 30 minutes after opening the cold water machine running, check the chiller running state is normal;

10. Cold water machine such as high and low water temperature reaches set temperature range of + / - 1 ℃ after high pressure on the checker running state is normal.

11. Check open suction fan or dust, exhaust fan or collector running state is normal, into a state cutting machine for cutting.



shutdown operation:

1. Remove the cutting head to high, X, Y axis and swap stopped in a safe place;

2. Closing device of high pressure and low pressure, GuanQi total power after 3 minutes, close the key switch;

3. According to the control panel scram button and close the key switch, exit the numerical control system, for page tip can shut off the power and turning off the power of the machine tool main control electric cabinet.

4. Close the cold water machine and person;

5. The regulated power supply;

6. The auxiliary gas;

7. Close the air compressor mechanical and electrical source, open air tank drain valve.