2656284142@qq.com

English

Seiko welding welding machine daily maintenance and maintenance

by:ZORON Machinery     2021-01-29
1, environmental requirements and cleaning:

1. The machine must be installed in the ventilation, dry environment, the environment temperature is not more than 35 ℃, equipment around the well ventilated, stay over 50 cm space with metope, especially behind the tank outlet shall ensure that ventilation is good.

2. Because of this machine is main part of the optical components, often should keep the external environmental health, clean is as follows:

A: equipment surrounding environment

B: light path dust cover





2, machine maintenance and maintenance:

1. Please make sure the water tank before starting the water reaches the specified location;

(2) the filter element found yellow or black to replace in time, change the time of 2 months;

3. (on a regular basis. 15 days or so) Cleaning dust network, the method to remove the filter directly compressed air spray or rinse with water;

(4) replacement of a tank of water, 30 days on a regular basis to ensure the condensing cavity clean, otherwise it will affect the energy;

3, regular replacement of xenon lamp:

1. Xenon lamp as one of the machine use consumables, due to the long time use device, xenon lamp energy will be reduced;

2. If the parameter is set in 160 - a 180 a, still can't will product welding, please replace the new xenon lamp;

3. The service life of the normal xenon lamp used in more than 3 million times or 4 months or so.

4, change protection lens:

(1) to protect the lens is also one of the machine consumables, installation to protect the lens is in order to protect the focusing lens from being damaged;

2. This machine to work long hours after a period of time, to protect the lens surface will have dirt, slag, proposed every time before and after the boot wipe the surface with brush mirror paper, unable to remove the replacement to ensure the output does not reduce the light transmittance.

5, simple troubleshooting:

(1) closed cabinet open, open the key switch no response;

A: measuring the main power cord whether there is voltage input;

B: see if urgent stop switch is pressed, Bounce rotate to the right) 。

(2) the normal starting power, on the right side of the screen under voltage

A: check the waterway is normal, Whether the tank alarm, whether to have running water) ;

B: power check on both ends of the xenon lamp electrode holder is loose;

C: check whether the xenon lamp aging or damage, Replace a) ; If the problem still not solved, please contact the manufacturer consulting and technical personnel.

3. In the process of the machine work energy suddenly become weak

A: check to see if the protection of the focusing mirror below lens damage;

B: check whether the tank water temperature is high;

C: open the light path dust cover, check for condensation cavity ( Will drip dry with paper towel) At the same time to see if there are any more water droplets (bar two end face Turned around to wipe gently with clean cotton swabs) ;

D: water tank is working, observe the ends of the bar whether there is water leakage ( If there is any outage) May seal is damaged, please contact the agent or vendor at this time to give telephone guidance or door-to-door service.

warm prompt:

the use of the natural environment changed due to the welding machine equipment, winter temperatures decrease if the environment temperature is lower than 5 ℃, please will be circulating water tank and the cavity body water, lest cause unnecessary loss.

we want more welding machine price, welcome to inquire, hotline:
Custom message
Chat Online 编辑模式下无法使用