To ensure the normal use of '' welding machine, stable performance and long service life, deal with equipment for routine maintenance.
'' welding machine is precision equipment, maintenance should be careful.
Below, ZuoLong machinery professional engineers will share YAG '' welding machine equipment maintenance knowledge.
a, '' welding machine equipment cleaning
every time before and after work, first make environment clean, the ground is dry, clean.
To prepare YAG '' welding machine equipment cleaning, including the outer surface of the chassis, observation system, countertops, etc shall be without sundry, clean.
Protective lens needs to keep clean.
2, '' welding machine cooling system maintenance
the maintenance of the cooling system, main is to regularly check the cooling water quality, water quality deterioration, opacity and transparency, new water should be replaced in a timely manner.
Regularly check the deposit of water in the tank, if the remaining water shortage should be added in time.
It is recommended to use this system deionized water or pure water.
regularly check whether the pipe joints have water leakage, leakage is tight on the screw to hold water.
When the xenon lamp and rod and cavity sealing it is leaking, deformation or aging, the main reason is that the rubber sealing ring is still leaking after tighten bolts, carefully check the rubber ring, if failed, the replacement of spare rubber ring.
3, '' welding machine system maintenance
1)
Clean the light path
system with its own light path, adopting closed design, general need not clean.
If necessary, according to the following methods: use lens paper or using alcohol to clean before and after optical lenses, keep the surface clean.
Take special care when wiping, unavailable so as not to damage the surface.
2)
Replace the xenon lamp
xenon lamp should be replaced periodically, usually in the use of 10 million times or so.
When the Nd3 + : YAG output significantly weakened or xenon lamp lit trouble, at this time should consider changing the xenon lamp.
Specific steps are as follows:
shut off the power, wait 10 minutes after open the lid.
Open cavity drainage switch, temperatures, and then drain switch lock.
See below
figure cavity installation schematic
apart at the ends of the lamp pump cavity line again lock screw and the insulation protective sleeve, and screw on the cover.
See below
figure remove electrode cover figure
light pressure on both ends of the pump cavity ring down the screw, head to the side take out xenon lamp, if the lamp with cavity fit is too tight, in the rubber sealing ring around add a few drops lubrication acetone or alcohol.
Pull the xenon lamp when it is important to note that cannot energetically, in order to avoid tube broken.
See below
figure out xenon lamp figure
good xenon lamp replacement by a xenon lamp direction insert, installed on both ends of the sealing ring and light pressure ring, guarantee the end pressure, xenon lamp is in middle position, the installation is the process down.
After installed, open the cooling circulating water, carefully check whether the joint of tube and condensing cavity is leaking.
Only when to ensure no leaking, can open the power, reset.
4 cavity, check the regulator
equipment operators can often use black paper detector output light spot, once found flare phenomenon such as uneven or energy decline, should timely adjust device of cavity, to ensure the output beam quality.
Debug the operator must have safety sense, work must wear special protective glasses.
Of the adjustment should be carried out by specially trained personnel, otherwise it will caused by disorder or adjust light damage to other components on the road.
the above is how of welding machine in the daily maintenance of the four methods to prolong the life of the machine advice, really good machine like people, are all need maintenance and maintenance.
Hope these Suggestions have guidance to help in your work.
we want more ', 'welding machine price, welcome to inquire, hotline: